beautypg.com

Environmental requirements, 25 environmental requirements – IBM AA-RWF3A-TE User Manual

Page 136

background image

Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions

beyond those for which it was tested. The ranges specified in

Table 25

list the acceptable

environment for both operating and non-operating conditions.

Table 25 Environmental requirements

Condition

Acceptable range during operation

Acceptable range during

non-operation

Ambient

temperature

0° to 40° Celsius (32° to 104°

Fahrenheit)

-25° to 70° Celsius (-13° to 158°

Fahrenheit)

Humidity

10% to 85% RH non-condensing, at

40° Celsius (104° Fahrenheit) , with

maximum gradient of 10% per hour

10% to 90% RH non-condensing, at

70° Celsius (158° Fahrenheit)

Altitude

3,000 meters (9,842 feet) above sea

level

0 to 12 kilometers (39,370 feet) above

sea level

Shock

20 G, 6 ms duration, half-sine wave

Half sine, 33G 11ms, 3/eg Axis

Vibration

0.5 G sine, 0.4 grms random, 5-500 Hz 2.0 G sine, 1.1 grms random 5-500

Hz

Airflow for 4/32

SAN Switch

24 cubic ft/minute

None required

Airflow for 4/8,

4/16, and 4/64

SAN Switches

47 cubic ft/minute

None required

Airflow for 4/32B

SAN Switch

High speed, 9300 RPM,

20.8 cubic feet/ minute

Low speed, 7200 RPM, 15.4 cubic feet/

minute

None required

NOTE:

The –10 ºC to +40 ºC range applies to the ambient air temperature at the air intake

vents on the nonport side of the switch. The temperature inside the switch can be up to

75 ºC during switch operation.
If the internal temperature range exceeds the operating ranges of the components,

the LEDs, error messages, and Fabric Watch alerts will indicate a problem. Issue the
tempshow

command to view temperature status.

136

SAN Switch technical specifications