3.2 Hardware Sensors
The following table lists the hardware sensors present on the STL2 server board.
Sensor Number
Sensor Type
Monitoring Device
01h
Temperature
ADM1024 Temperature
02h
Processor 1 internal
03h
Processor 2 internal
20h
Voltage
3.3V
21h
5V
22h
12V
23h
3.3V Standby
24h
Processor 1
25h
Processor 2
29h
1.5V
2Ah
2.5V
2Ch
SCSI-A 2.85V
2Dh
SCSI-B 2.85V
2Eh
SCSI-A Vref1
2Fh
SCSI-A Vref2
30h
SCSI-A Vref3
31h
SCSI-B Vref1
32h
SCSI-B Vref2
33h
SCSI-B Vref3
34h
Voltage (Discrete)
Performance Lags
40h
Fan
Baseboard Fan 1
41h
Baseboard Fan 2
42h
Baseboard Fan 3
60h
Processor
Processor 1 State
61h
Processor 2 State
70h
Power Distribution Board
Soft Power Control Failure (bit 5) Interlock Power
71h
Power Distribution Board Supply 1
Power supply Failure detected (bit 1)
72h
Power Distribution Board Supply 2
Power supply Failure detected (bit 1)
7Fh
Power Redundancy Lost
Redundancy Lost (bit 1)
Redundancy Regained (bit 0)
90h
Chassis Intrusion ID
Drive Bay Intrusion (bit 1)
LAN Leash Lost (bit 4)
91h
Security Violation
Secure Mode Violation Attempt (bit 0)
92h
Memory Error
ECC multiple bit error (bit 1)
ECC single bit error (bit 0)
93h
POST Memory Resize