Henny Penny OFE/OFG-322 User Manual
Page 20

Model OFE/OFG-321,322,323,324
2-18. HEATING ELEMENTS
(ELECTRIC ONLY)
(Continued)
9. Evenly space the element spreaders on the sides of the
elements and reinstall bolts. Place the fifth spreader in the
front of the elements as to protect the temperature probe.
(Fig.6-1
10. Replace the high limit bulb holder on the top element, and
position the bulb between the top and second element
midway from side to side, and tighten screw that holds the
bulb
in
place.
11. Reconnect the wires to the appropriate terminal as labeled
when they were removed.
Temperature Spreader
Probe
Fig. 2-1
12. Replace the front control panel.
13. Connect the power cord to the wall receptacle or close wall
circuit
breaker.
Heating elements should never be energized without
shortening in the frypot, or damage to the elements could
result.
14. Replace the shortening in the frypot.
Fig. 2-2
2-20
203