Henny Penny OFE/OFG-322 User Manual
Page 10
Model OFE/OFG-321,322,323,324
2-9. IGNITOR MODULE
During normal operation, the ignition modules send 24 volts to the
ignitors and gas control valve. If a module does not sense a pilot
flame, the module starts the ignition process again. But, if a pilot
light goes out for longer that 10 seconds, or it goes out 3 times within
10 seconds, the module keeps the 24 volts from reaching the gas
control valve. The burners shut down.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel as discussed in Complete Control Panel
Replacement Section.
3. Label and remove the wires at module.
4. Using a 3/8 inch nut driver, remove the keps nuts securing the
module to the shroud.
5. Install new module in reverse order.
2-10. TRANSFORMER
The transformer reduces voltage down to accommodate those
components with low voltage.
1. Remove electrical power supplied to the unit.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Remove the control panel as discussed in Complete Control Panel
Replacement Section.
3. Squeeze on the wire connector at the I/O board assembly to
disconnect the wires from the transformer.
4. Using a Phillips head screwdriver, remove the two screws
securing the transformer to the shroud.
5. Install the new transformer in reverse order.
2-10
203