beautypg.com

Henny Penny OFE/OFG-322 User Manual

Page 10

background image

Model OFE/OFG-321,322,323,324



2-9. IGNITOR MODULE

During normal operation, the ignition modules send 24 volts to the
ignitors and gas control valve. If a module does not sense a pilot
flame, the module starts the ignition process again. But, if a pilot
light goes out for longer that 10 seconds, or it goes out 3 times within
10 seconds, the module keeps the 24 volts from reaching the gas
control valve. The burners shut down.

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

2. Remove the control panel as discussed in Complete Control Panel

Replacement Section.


3. Label and remove the wires at module.

4. Using a 3/8 inch nut driver, remove the keps nuts securing the

module to the shroud.

5. Install new module in reverse order.

2-10. TRANSFORMER

The transformer reduces voltage down to accommodate those
components with low voltage.

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the

POWER switch to OFF and disconnect main circuit

breaker, or unplug cord at wall receptacle.

2. Remove the control panel as discussed in Complete Control Panel

Replacement Section.


3. Squeeze on the wire connector at the I/O board assembly to

disconnect the wires from the transformer.

4. Using a Phillips head screwdriver, remove the two screws

securing the transformer to the shroud.

5. Install the new transformer in reverse order.


2-10

203

This manual is related to the following products: