2-15. FILTER SWITCH
(Continued)
2. Remove the control panel above the switch.
3. Label and remove the wires from the switch. With test
instrument, check across the terminals of the switch with the
switch in the ON position, and then in the OFF position. With
the switch in the ON position, the circuit should be closed.
With the switch in the OFF position, the circuit should be open.
If the switch checks defective, replace it by continuing with
this
procedure.
4. With wires removed from the switch, push in on tabs on the
switch and remove switch from the panel.
5. Push new switch into panel and reconnect wires.
2-16. GAS CONTROL VALVE
ASSEMBLY
The gas control valve assembly controls the flow of gas to the pilot
and the main burner. The valve has two 24 volt coils, which are
regulated by terminals P and M on the valve. The C terminal is the
common terminal. For gas flow to the pilot, 24 VAC must be
present between the P and C terminals. For gas flow to the main
burner, 24 VAC must be present between the M and C terminals.
TO AVOID PERSONAL INJURY OR PROPERTY
DAMAGE,
BEFORE
STARTING
THIS
PROCEDURE,
MOVE
THE
MAIN
POWER
SWITCH
TO
THE
OFF
POSITION. DISCONNECT THE MAIN
CIRCUIT
BREAKERS
AT
THE
CIRCUIT
BREAKER
BOX OR UNPLUG SERVICE CORD FROM WALL
RECEPTACLE. TURN OFF THE MAIN GAS
SUPPLY TO THE FRYER AND DISCONNECT AND
CAP THE MAIN SUPPLY LINE TO FRYER, OR
POSSIBLE
EXPLOSION
COULD
RESULT.
1. Remove control panel assembly.
2. Remove wires from gas control valve.