2-17. BLOWER MOTOR
ASSEMBLY
(Continued)
8. Using 3/8 inch nut driver, remove nuts securing blower to the
unit.
Pull
blower
from
unit.
9. Install new blower in reverse order.
2-18. HEATING ELEMENTS
(ELECTRIC ONLY)
Heating elements are available for 208 and 230 volts. Check
data
plate
to
determine
correct
voltage.
Checkout:
If the shortenings temperature recovery is very slow or at a slower
rate than required, this may indicate defective heating element(s).
An ohmmeter will quickly indicate if the elements are shorted or
open.
1. Remove electrical power supplied to the frypot to be worked on.
To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle, to the frypot
to be worked on. Be aware the other controls will have
power.
2. Remove control panel.