LED States

LEDs located on DL.1 fixture boards indicate how the unit is functioning. Table 5-1
lists LED States, and problems they may indicate. For details on locating board
LEDs, see Figure 5-8 on page 5-10.

Table 5-1 LED States

LED

Location

LED #

State

Problem?

Description

2-phase
Board

LD1

LD2

LD3

LD4

Steady Green

No

S3 (dimming iris) sensor open

Steady Yellow

No

S3 (dimming iris) sensor closed

Blinking Red

No

Board is initializing

Infinitely
Blinking Red

Yes

Board not receiving data

Steady red

Yes

Board not receiving data

Blinking Red
and Green

Yes

Addressing screw(s) missing from board

OFF

Yes

Board not receiving power

LD5

Steady Green

No

Receiving proper voltage

Blinking Dim
Green

No

Receiving data

Dim Green

Yes

Board not receiving data

OFF

Yes

Board not receiving power

3-phase
Boards

LD1

Steady Green

No

Board receiving proper voltage

Dim Green

Yes

Board not receiving data

OFF

Yes

Board not receiving power

LD2

Blinking Red

Yes

Board not programmed

LD3

Steady Green

No

Board programmed properly

Blinking Red

Yes

Board not programmed