General troubleshooting, Led states, General troubleshooting -8 – High End Systems DL1 User Manual
Page 68: Led states -8
5-8
General Maintenance and Troubleshooting
DL.1 User Manual
Caution: The fixture will not function correctly if contact screws are missing
from boards.
6. Replace the side assembly. Make sure you align the assembly properly when
inserting; damage to the fixture can result from improper alignment.
7. Replace the six M4 socket caps that secure the side assembly to the fixture.
General Troubleshooting
This section discusses troublehsooting LED states and general troubleshooting
suggestions.
LED States
LEDs located on DL.1 fixture boards indicate how the unit is functioning. Table 5-1
lists LED States, and problems they may indicate. For details on locating board
LEDs, see Figure 5-8 on page 5-10.
Table 5-1 LED States
LED
Location
LED #
State
Problem?
Description
2-phase
Board
LD1
LD2
LD3
LD4
Steady Green
No
S3 (dimming iris) sensor open
Steady Yellow
No
S3 (dimming iris) sensor closed
Blinking Red
No
Board is initializing
Infinitely
Blinking Red
Yes
Board not receiving data
Steady red
Yes
Board not receiving data
Blinking Red
and Green
Yes
Addressing screw(s) missing from board
OFF
Yes
Board not receiving power
LD5
Steady Green
No
Receiving proper voltage
Blinking Dim
Green
No
Receiving data
Dim Green
Yes
Board not receiving data
OFF
Yes
Board not receiving power
3-phase
Boards
LD1
Steady Green
No
Board receiving proper voltage
Dim Green
Yes
Board not receiving data
OFF
Yes
Board not receiving power
LD2
Blinking Red
Yes
Board not programmed
LD3
Steady Green
No
Board programmed properly
Blinking Red
Yes
Board not programmed