F-1000MRF

AC SUPPLY VOLTAGE

208-230/60/1 (3 wire with neutral for 115V)

COMPRESSOR

240 V

4.2 RLA

34 LRA

GEAR MOTOR

120 V

1.6 FLA

1/6 HP

FAN MOTOR REMOTE

120 V

3 A MAX

OTHER

120 V

0.03A

MAXIMUM FUSE SIZE

15 A

MAX. HACR BREAKER (USA ONLY)

15 A

MAX. CIRC. BREAKER (CANADA ONLY)

15 A

MINIMUM CIRCUIT AMPACITY

15 A

APPROXIMATE ICE PRODUCTION

Ambient

W ATER TEMP. (°F)

PER 24 HR.

Temp.(°F)

50

70

90

lbs./day ( kg/day )

70

*930 (422)

895 (407)

865 (393)

Reference without *marks

80

835 (379)

805 (366)

780 (353)

90

750 (341)

*745 (338)

700 (317)

100

675 (306)

650 (296)

605 (274)

SHAPE OF ICE

Flake

ICE QUALITY

Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm)

APPROXIMATE STORAGE CAPACITY

N/A

ELECTRIC & WATER CONSUMPTION

90/70°F

70/50°F

ELECTRIC W (kWH/100 lbs.)

1295 (4.2)

1285 (4.5)

POTABLE W ATER

89 (12)

111(12)

gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (W xDxH)

22" x 27-3/8" x 25-1/4" (560 x 695 x 642mm)

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

W EIGHT

Net 172 lbs. ( 78 kg ), Shipping 198 lbs. ( 90 kg )

CONNECTIONS - ELECTRIC

Permanent - Connection

- WATER SUPPLY

Inlet 1/2" FPT

- DRAIN

Outlet 3/4" FPT

- REFRIGERATION

Discharge line 1-1/16-12 UNF Fitting (#10 AEROQUIP)

CIRCUIT

Liquid line 5/8-18 UNF Fitting (#6 AEROQUIP)

ICE MAKING SYSTEM

Auger type

HARVESTING SYSTEM

Direct Driven Auger ( 1/6 HP Gear Motor )

ICE MAKING WATER CONTROL

Float Switch

COOLING W ATER CONTROL

N/A

BIN CONTROL SYSTEM

Mechanical Bin Control ( Proximity Sw. )

COMPRESSOR

Hermetic, Model RS70-C1E-PFV

CONDENSER

Air-cooled Remote Condenser unit URC-6F Recommended

EVAPORATOR

Copper Tube on Cylinder

REFRIGERANT CONTROL

Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-6F

REFRIGERANT CHARGE

R-404A,

4 lb.1oz.

(1850g)

(Ice Maker: 2 lb. 3 oz., Cond. Unit: 1 lb. 14 oz. )

DESIGN PRESSURE

High 427 PSIG, Low 230 PSIG

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-off Relay

COMPRESSOR PROTECTION

Internal Protector

GEAR MOTOR PROTECTION

Manual reset Circuit Breaker or Fuse

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

LOW W ATER PROTECTION

Float Switch and Timer

ACCESSORIES -SUPPLIED

Spare Fuse

-REQUIRED

Ice Storage Bin

OPERATING CONDITIONS

VOLTAGE RANGE

187-253 V

AMBIENT TEMP.

45-100° F

W ATER SUPPLY TEMP.

45-90° F

W ATER SUPPLY PRESSURE

10-113 PSIG

DRAWING NO. (DIMENSION)

3A0983

We reserve the right to make changes in specifications and design without prior notice.