Hoshizaki MODULAR FLAKER F-1000MAF/-C User Manual
Page 48
![background image](/manuals/94305/48/background.png)
48
F-1000MLF-C
We reserve the right to make changes in specifications and design without prior notice.
APPROXIMATE
Ambient
Water Temp. (°F)
ICE PRODUCTION
Temp. (°F)
PER 24 HR.
70
1020
(463)
945
(428)
915
(415)
80
885
(402)
860
(390)
835
(378)
90
805
(366)
795
(361)
760
(344)
lbs./day (kg/day)
100
735
(333)
710
(323)
640
(290)
APPROXIMATE ELECTRIC
70
140
--
140
--
140
--
CONSUMPTION
80
140
--
135
--
135
--
90
135
--
135
--
135
--
watts
100
135
--
135
--
135
--
APPROXIMATE WATER
70
122
(463)
113
(428)
110
(415)
CONSUMPTION PER 24 HR.
80
106
(402)
103
(390)
100
(378)
90
97
(366)
95
(361)
91
(344)
gal./day (l/day)
100
88
(333)
86
(323)
77
(290)
EVAPORATOR OUTLET TEMP.
70
21
(-6)
21
(-6)
21
(-6)
80
21
(-6)
21
(-6)
21
(-6)
90
21
(-6)
21
(-6)
23
(-5)
°F (°C)
100
23
(-5)
23
(-5)
23
(-5)
HEAD PRESSURE
70
106
(7.4)
106
(7.4)
106
(7.4)
80
125
(8.7)
125
(8.7)
125
(8.7)
90
143
(10.0)
143
(10.0)
143
(10.0)
PSIG (kg/cm²G)
100
166
(11.7)
166
(11.7)
166
(11.7)
SUCTION PRESSURE
70
26
(1.8)
26
(1.8)
26
(1.8)
80
30
(2.1)
30
(2.1)
30
(2.1)
90
33
(2.3)
33
(2.3)
33
(2.3)
PSIG ( kg/cm²G )
100
35
(2.5)
35
(2.5)
35
(2.5)
Note: The data without *marks should be used for reference.
This data is for reference only, different condensing unit will vary data.
50
70
90