Hoshizaki MODULAR FLAKER F-1000MAF/-C User Manual
Page 46

46
F-1000MWF-C
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
790
(358)
760
(346)
750
(340)
80
735
(333)
720
(327)
710
(322)
90
695
(316)
685
(311)
670
(304)
lbs./day (kg/day)
100
660
(299)
645
(294)
600
(272)
APPROXIMATE ELECTRIC
70
1160
--
1170
--
1185
--
CONSUMPTION
80
1160
--
1170
--
1185
--
90
1160
--
1170
--
1185
--
watts
100
1160
--
1170
--
1185
--
APPROXIMATE WATER
70
398
(1.81)
534
(2.43)
859
(3.91)
CONSUMPTION PER 24 HR.
80
414
(1.88)
554
(2.52)
898
(4.08)
(TOTAL)
90
427
(1.94)
574
(2.61)
939
(4.27)
gal./day (l/day)
100
442
(2.01)
598
(2.72)
1032
(4.69)
EVAPORATOR OUTLET TEMP.
70
23
(-5)
23
(-5)
25
(-4)
80
23
(-5)
23
(-5)
25
(-4)
90
23
(-5)
23
(-5)
25
(-4)
°F (°C)
100
23
(-5)
23
(-5)
25
(-4)
HEAD PRESSURE
70
263
(18.5)
266
(18.7)
269
(18.9)
80
263
(18.5)
266
(18.7)
269
(18.9)
90
263
(18.5)
266
(18.7)
269
(18.9)
PSIG (kg/cm²G)
100
263
(18.5)
266
(18.7)
269
(18.9)
SUCTION PRESSURE
70
33
(2.3)
34
(2.4)
35
(2.5)
80
33
(2.3)
34
(2.4)
35
(2.5)
90
33
(2.3)
34
(2.4)
35
(2.5)
PSIG ( kg/cm²G )
100
33
(2.3)
34
(2.4)
35
(2.5)
WATER FLOW FOR CONDENSER
40 gal/h (AT 90°F /WT 70°F)
PRESSURE DROP OF COOLING WATER LINE
Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER
7110 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR
1340 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50
70
90
We reserve the right to make changes in specifications and design without prior notice.