5. PERFORMANCE DATA
F-1000MAF
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
970
(440)
930
(422)
890
(404)
80
855
(388)
820
(372)
785
(357)
90
755
(342)
740
(336)
695
(314)
lbs./day (kg/day)
100
665
(301)
635
(289)
595
(270)
APPROXIMATE ELECTRIC
70
1160
--
1165
--
1170
--
CONSUMPTION
80
1175
--
1185
--
1190
--
90
1195
--
1200
--
1205
--
watts
100
1210
--
1215
--
1220
--
APPROXIMATE WATER
70
116
(440)
112
(422)
107
(404)
CONSUMPTION PER 24 HR.
80
103
(388)
98
(372)
94
(357)
90
90
(342)
89
(336)
83
(314)
gal./day (l/day)
100
80
(301)
76
(289)
71
(270)
EVAPORATOR OUTLET TEMP.
70
19
(-7)
19
(-7)
19
(-7)
80
19
(-7)
23
(-5)
23
(-5)
90
23
(-5)
23
(-5)
25
(-4)
°F (°C)
100
25
(-4)
25
(-4)
25
(-4)
HEAD PRESSURE
70
213
(15.0)
213
(15.0)
213
(15.0)
80
244
(17.1)
244
(17.1)
244
(17.1)
90
274
(19.3)
274
(19.3)
274
(19.3)
PSIG (kg/cm²G)
100
315
(22.1)
315
(22.1)
315
(22.1)
SUCTION PRESSURE
70
32
(2.3)
32
(2.3)
32
(2.3)
80
35
(2.5)
35
(2.5)
35
(2.5)
90
38
(2.6)
38
(2.6)
38
(2.6)
PSIG ( kg/cm²G )
100
41
(2.9)
41
(2.9)
41
(2.9)
TOTAL HEAT OF REJECTION
5090 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50
70
90
We reserve the right to make changes in specifications and design without prior notice.