Hoshizaki MODULAR FLAKER F-1000MAF/-C User Manual
Page 42

42
F-1000MWF
APPROXIMATE
Ambient
Water Temp. (F)
ICE PRODUCTION
Temp. (F)
PER 24 HR.
70
890
(404)
855
(389)
840
(380)
80
820
(372)
805
(364)
785
(356)
90
770
(349)
755
(342)
735
(334)
lbs./day (kg/day)
100
720
(327)
705
(320)
655
(297)
APPROXIMATE ELECTRIC
70
1155
--
1160
--
1185
--
CONSUMPTION
80
1155
--
1160
--
1185
--
90
1155
--
1160
--
1185
--
watts
100
1155
--
1160
--
1185
--
APPROXIMATE WATER
70
410
(1.86)
526
(2.39)
811
(3.69)
CONSUMPTION PER 24 HR.
80
427
(1.94)
548
(2.49)
853
(3.88)
(TOTAL)
90
443
(2.01)
571
(2.59)
898
(4.08)
gal./day (l/day)
100
461
(2.09)
599
(2.72)
989
(4.49)
EVAPORATOR OUTLET TEMP.
70
23
(-5)
23
(-5)
25
(-4)
80
23
(-5)
23
(-5)
25
(-4)
90
23
(-5)
23
(-5)
25
(-4)
°F (°C)
100
23
(-5)
23
(-5)
25
(-4)
HEAD PRESSURE
70
263
(18.5)
266
(18.7)
269
(18.9)
80
263
(18.5)
266
(18.7)
269
(18.9)
90
263
(18.5)
266
(18.7)
269
(18.9)
PSIG (kg/cm²G)
100
263
(18.5)
266
(18.7)
269
(18.9)
SUCTION PRESSURE
70
33
(2.3)
34
(2.4)
35
(2.5)
80
33
(2.3)
34
(2.4)
35
(2.5)
90
33
(2.3)
34
(2.4)
35
(2.5)
PSIG ( kg/cm²G )
100
33
(2.3)
34
(2.4)
35
(2.5)
WATER FLOW FOR CONDENSER
38 gal/h (AT 90°F /WT 70°F)
PRESSURE DROP OF COOLING WATER LINE
Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER
7110 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR
1340 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50
70
90
We reserve the right to make changes in specifications and design without prior notice.