42

F-1000MWF

APPROXIMATE

Ambient

Water Temp. (F)

ICE PRODUCTION

Temp. (F)

PER 24 HR.

70

890

(404)

855

(389)

840

(380)

80

820

(372)

805

(364)

785

(356)

90

770

(349)

755

(342)

735

(334)

lbs./day (kg/day)

100

720

(327)

705

(320)

655

(297)

APPROXIMATE ELECTRIC

70

1155

--

1160

--

1185

--

CONSUMPTION

80

1155

--

1160

--

1185

--

90

1155

--

1160

--

1185

--

watts

100

1155

--

1160

--

1185

--

APPROXIMATE WATER

70

410

(1.86)

526

(2.39)

811

(3.69)

CONSUMPTION PER 24 HR.

80

427

(1.94)

548

(2.49)

853

(3.88)

(TOTAL)

90

443

(2.01)

571

(2.59)

898

(4.08)

gal./day (l/day)

100

461

(2.09)

599

(2.72)

989

(4.49)

EVAPORATOR OUTLET TEMP.

70

23

(-5)

23

(-5)

25

(-4)

80

23

(-5)

23

(-5)

25

(-4)

90

23

(-5)

23

(-5)

25

(-4)

°F (°C)

100

23

(-5)

23

(-5)

25

(-4)

HEAD PRESSURE

70

263

(18.5)

266

(18.7)

269

(18.9)

80

263

(18.5)

266

(18.7)

269

(18.9)

90

263

(18.5)

266

(18.7)

269

(18.9)

PSIG (kg/cm²G)

100

263

(18.5)

266

(18.7)

269

(18.9)

SUCTION PRESSURE

70

33

(2.3)

34

(2.4)

35

(2.5)

80

33

(2.3)

34

(2.4)

35

(2.5)

90

33

(2.3)

34

(2.4)

35

(2.5)

PSIG ( kg/cm²G )

100

33

(2.3)

34

(2.4)

35

(2.5)

WATER FLOW FOR CONDENSER

38 gal/h (AT 90°F /WT 70°F)

PRESSURE DROP OF COOLING WATER LINE

Less than 7 PSIG

HEAT OF REJECTION FROM CONDENSER

7110 BTU/h (AT 90°F /WT 70°F)

HEAT OF REJECTION FROM COMPRESSOR

1340 BTU/h (AT 90°F /WT 70°F)

Note: The data without *marks should be used for reference.