beautypg.com

Finishing, Warning, A. mantel projections – Hearth and Home Technologies Heat & Glo Twilight II-B User Manual

Page 21: B. facing material

background image

Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. G • 8/07

21

12

11

10

9

8

7

6

13-5/8

12-5/8

11-5/8

10-5/8

9-5/8

8-5/8

7-5/8

HOOD

NON-COMBUSTIBLE BOARD

(SUPPLIED ON APPLIANCE)

INDOOR SIDE ONLY

CEILING

35-3/4

A. Mantel Projections

Figure 8.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge of
the appliance.

8

8

Finishing

B. Facing Material

Fire Risk.

Do NOT obstruct air inlet or outlet grilles.

Do NOT modify grilles.

• Modifying or covering grilles could cause

temperature rise and fi re hazard.

Finishing materials must not interfere with:

• Air fl ow through grilles or louvers.

• Operation of louvers or doors.

• Access for service.

Inside Facing Material

• May install combustible materials up to specified

clearances on top, front and sides of appliance.

• Seal joints between fi nished wall and appliance top and

sides with 300º F (140º

C) minimum sealant.

• Leave space so bottom grille can be lowered for trim

door removal.

41-7/8 in.

2-3/4 in.

NON-COMBUSTIBLE ZONE

Figure 8.1 Indoor Clearances to Mantels or other
Combustibles

above

Appliance

Note: Measurements
are in inches.

Interior
View

Figure 8.3 Non-combustible Zone (Interior)

Outside Facing Material

Figure 8.2 Clearances to Combustible Mantel Leg or Wall

Projections (Acceptable on both sides of opening.)

Top View

WARNING

MEASURED

FROM CORNER

FIREPLACE

HOOD

½ IN.

Figure 8.4 Exterior View - Minimum Clearances

Vinyl

Non-vinyl

A

36 in.

12 in.

B

64-5/16 in.

35-5/16 in.

OVERHANG

A

A

A

B

SIDING

SIDING

SIDING