Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. G • 8/07

19

Figure 7.3 Intellifi re Pilot Ignition (IPI) Wiring Diagram

*

NOTE: 1. Ignition module, valve, pilot, and wall switch operate on 3 volts.
Uninterrupted 120 VAC is required at junction box unless equipped with battery back-up.

D. Intellifi re Ignition System Wiring

This appliance requires a 110 VAC supply to the appliance
junction box for operation. When using the transformer,
the junction box must have uninterrupted 120V. A wiring
diagram is shown in Figure 7.3.

This appliance is equipped with an Intellifi re control valve
which operates on a 3 volt system.

This appliance is supplied with a battery pack and a 3 volt AC
transformer, which requires the installation of the supplied
junction box. It is highly recommended that the junction box
be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not included).

CAUTION

Battery polarity must be correct or module damage will occur.

Optional Accessories Requirements

Wiring for optional accessories should be done now to
avoid reconstruction.

IGNITION MODULE

3 VAC

TRANSFORMER

3 VAC

GRN

ORG

INTERMITTENT

PILOT

IGNITOR

IGNITION

MODULE

(3V)

ON/OFF

WALL

SWITCH

LOW VOLTAGE

PLUG-IN

3V TRANSFORMER

NEUTRAL

HOT

GROUND

FLAME SPARKER/

SENSOR

REMOTE

CONTROL

SEE NOTE 1

ORG

WHT

VALVE

PIGGYBACK

ON/OFF SWITCH

WHITE WIRE

CAN BE

PLUGGED

INTO ANY

OF #1-#5

LOCATIONS

ON THE

NEUTRAL SIDE

BLACK WIRE CAN BE

PLUGGED INTO ANY OF

#1 - #5 LOCATIONS

ON THE HOT SIDE

BRN

BRN

VALVE

PLUG IN

GROUND TO
FIREPLACE
CHASSIS

I

S

NOTE: Batteries cannot be placed in the battery pack while
using the 3 volt AC transformer. The transformer must be
unplugged if the battery pack is used or battery life will be
reduced.