Termination locations, Warning, A. appliance opening minimum clearances – Hearth and Home Technologies Heat & Glo Twilight II-B User Manual
Page 10

Heat & Glo LifeStyle Collection • Twilight-II-B • 2108-900 Rev. G • 8/07
10
D
E
L
FP
A
H
M
X
J or K
I
A
G
F
FP
FP
FP
FP
FP
B
B
B
4
4
Termination Locations
FP
= APPLIANCE OPENING
X
= AIR SUPPLY INLET
= AREA WHERE APPLIANCE IS NOT PERMITTED
J =
9”
(U.S.A.)
12” (Canada)
...........clearance to non-mechani-
cal air supply inlet to building
or the combustion air inlet to
any other appliance
K
= 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical
air supply inlet
L** = 54” ...........................clearance above paved side-
walk or a paved driveway lo-
cated on public property
M*** = 35-5/16”...................clearance under veranda,
porch, deck, balcony or over-
hang
64-5/16”
..................vinyl
N
= 12” ..........................non-vinyl siding
36” ..........................vinyl siding
P =
8
ft.
(See Note 1)
(See Note 1)
(See Note 2)
*
36” minimum for vinyl windows or vinyl siding.
** a appliance shall not open directly above a sidewalk or paved
driveway which is located between two single family dwellings
and serves both dwellings.
*** only permitted if veranda, porch, deck or balcony is fully open on
a minimum of 2 sides beneath the fl oor, or if the screened porch
guidelines are followed.
NOTE 1: Local codes or regulations may require different clearances.
NOTE 2: Termination in an alcove space (spaces open only on one side
and with an overhang) are permitted with the dimensions specifi ed for
vinyl or non-vinyl siding and soffi ts. 1. There must be 3 feet minimum
between terminations or between the appliance and termination. 2.
All mechanical air intakes within 10 feet of a termination must be a
minimum of 3 feet below the appliance hood. 3. All gravity air intakes
within 3 feet of the appliance hood must be a minimum of 1 foot below
the termination.
This appliance is approved for installation onto screened porches
with the following guidelines:
Fire Risk. Explosion Risk.
Maintain vent termination minimum clearances as specifi ed.
Figure 4.1 Minimum Clearances for Appliance Opening
NOTE: There may be some odor and small amounts of soot
associated with venting the Twilight-II-B onto a screened porch.
Ensuring good cross draft ventilation and routine maintenance of
the appliance will maximize comfort and cleanliness.
Minimum porch area: 96 square feet
Minimum ceiling height: 92 inches
Minimum two walls must be screened
Minimum top of screen height, side walls: 6 ft. 8 in.
Minimum screen area: 64 square feet
A. Appliance Opening Minimum Clearances
M
N
P
R
Q
FP
A
= 0” ...........................clearances above grade, veran-
da, porch, deck or balcony
B*
= 12”
.........................clearances to window or door
that may be opened, or to per-
manently closed window.
D
=.................................vertical clearance to ventilated
soffi t located above the hood
within a horizontal distance of 2
feet (60 cm) from the center-line
of the hood
E
= .. .clearance to unventilated soffi t
F
= 9” ..........................clearance to outside corner
G*
= 12” .........................clearance to inside corner
H
= 3 ft. (Canada) ........not to be installed above a gas me-
ter/regulator assembly within 3 feet
(90cm) horizontally from the center-
line of the regulator
I
= 3 ft. ........................clearance to service regulator vent
outlet and electric service
35-5/16”
(non-vinyl)
64-5/16”
(vinyl)
35-5/16”
(non-vinyl)
64-5/16”
(vinyl)
WARNING
Q
MIN
R
MAX
Twilight-II-B
10 feet
2 x Q
ACTUAL
1 additional termination cap
Q + 3 feet
1 x Q
ACTUAL
2 additional termination caps
Q + 6 feet
2/3 x Q
ACTUAL
3 additional termination caps
Q + 9 feet
1/2 x Q
ACTUAL
R
MAX
= (2 / # caps plus appliance) x Q
ACTUAL