beautypg.com

2013 addendum – Hoshizaki KM-1601SAH/3 User Manual

Page 77

background image

2013 ADDENDUM

A. Dip Switch Settings

1) S4 Dip Switch Settings

S4 Dip Switch

Model

Auxiliary Code

Dip Switch No.

1

2

3

4

5

6

7

8

9

10

KM-1601SWH/3 B-1 and Later

OFF OFF OFF OFF ON ON OFF OFF OFF ON

KM-1601SRH/3 B-1 and Later

ON OFF OFF OFF ON ON OFF OFF OFF OFF

2) S5 Dip Switch Settings

S5 Dip Switch (Do Not Adjust)

Model

Auxiliary Code

Dip Switch No.

1

2

3

4

5

KM-1601SWH/3 B-1 and Later

OFF OFF OFF OFF OFF

KM-1601SRH/3 B-1 and Later

OFF OFF OFF OFF OFF

1

2

3

4

5

ON

1

2

3

4

5

6

7

8

9

10

ON

Freeze Timer (9 & 10)

Pump-Out Frequency Control (5 & 6)

Pump-Out Timer (3 & 4)

Harvest Timer (1 & 2)

Harvest Pump Timer (7) (Do not adjust)

Factory Use (8)

S4 Dip Switch

Do Not Adjust

S5 Dip Switch

Refill Counter

(2 through 5)

Float Switch

Selector (1)

A-1