beautypg.com

Hoshizaki KM-1601SAH/3 User Manual

Page 45

background image

45

2. KM-1601SAH3 (air-cooled)

Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in

bold

should be used for reference only.

2. We reserve the right to make changes in specifications and design without prior

notice.

70/21

1456

660

1423

646

1313

596

80/27

1431

649

1381

626

1234

560

90/32

1423

646

1345

610

1211

549

lbs./day kg./day

100/38

1379

626

1314

596

1088

494

70/21
80/27
90/32

watts

100/38

70/21

708

2.68

573

2.17

510

1.93

80/27

605

2.29

396

1.50

400

1.51

90/32

573

2.17

249

0.94

222

0.84

gal./day m

3

/day

100/38

422

1.60

243

0.92

198

0.75

70/21
80/27
90/32

min.

100/38

70/21
80/27
90/32

min.

100/38

70/21

267

18.8

291

20.5

316

22.2

80/27

286

20.1

323

22.7

343

24.1

90/32

291

20.5

350

24.6

372

26.1

PSIG kg/cm

2

G

100/38

293

20.6

355

25.0

392

27.6

70/21

41

2.9

45

3.1

48

3.4

80/27

44

3.1

49

3.5

52

3.7

90/32

45

3.1

53

3.7

57

4.0

PSIG kg/cm

2

G

100/38

45

3.2

54

3.8

60

4.2

24,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

2.2

TOTAL HEAT OF REJECTION FROM CONDENSER

SUCTION PRESSURE

HARVEST CYCLE TIME

HEAD PRESSURE

3.8
3.2

4.1

2.3

2.4

4.2

2463
2515
2610
2610

33
35
37
39

2420

2440
2533
2610
2610

2370
2424
2440

WATER TEMP. (ºF/ºC)

AMBIENT TEMP.

(ºF/ºC)

50/10

70/21

90/32

APPROXIMATE ICE

PRODUCTION PER 24 HR.

APPROXIMATE ELECTRIC

CONSUMPTION

APPROXIMATE WATER

CONSUMPTION PER 24 HR.

FREEZING CYCLE TIME

30
32

2.4

4.8

3.3

4.1
3.1

28
30

34

30
31

33