5. KM-1601SRH with URC-21F (remote air-cooled) (auxiliary codes: R-0; R-1; some S-1)
This data applies to units with an 8 l/min water valve. The 8 l/min water valve is part
number 3U0111-02 and has J248-032 stamped on the side of the valve facing the rear of
the unit.
70/21
1583
718
1550
703
1435
651
80/27
1558
707
1507
684
1353
614
90/32
1550
703
1472
668
1332
604
lbs./day kg./day
100/38
1503
682
1439
653
1203
546
70/21
80/27
90/32
watts
100/38
70/21
503
1.90
430
1.63
396
1.50
80/27
448
1.69
335
1.27
336
1.27
90/32
430
1.63
255
0.96
240
0.91
gal./day m
3
/day
100/38
348
1.32
251
0.95
226
0.86
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
201
14.1
215
15.1
235
16.5
80/27
211
14.9
233
16.4
254
17.8
90/32
215
15.1
248
17.4
269
18.9
PSIG kg/cm
2
G
100/38
219
15.4
253
17.8
288
20.2
70/21
36
2.5
38
2.7
41
2.9
80/27
38
2.6
41
2.9
44
3.1
90/32
38
2.7
43
3.0
47
3.3
PSIG kg/cm
2
G
100/38
39
2.7
44
3.1
50
3.5
CONDENSER VOLUME
441 CU. IN (URC-21F)
23
23
25
3.2
6.7
4.6
5.7
4.3
3.2
5.9
22
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
2507
2499
2576
2640
2655
2440
2485
2499
26
28
29
31
2564
2633
2703
2760
27
23
24
26
3.2
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
5.4
4.6
5.7
3.2
TOTAL HEAT OF REJECTION FROM CONDENSER
24,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior