Hoshizaki KM-1601SAH/3 User Manual
Page 12
12
7. KM-1601SRH with URC-22F (remote air-cooled) (auxiliary codes: S-2 and later)
This data applies to units with an 11 l/min water valve. The 11 l/min water valve is either
part number 4A1176-04 or 4A5251-04 and has the part number stamped on the side of
the valve facing the front of the unit.
Note: We reserve the right to make changes in specifications and design without prior
notice.
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE
12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*1531 (694)
1519 (689)
1426 (647)
Reference without *marks
80
1522 (690)
1503 (682)
1368 (620)
90
1519 (689)
*1490 (676)
1371 (622)
100
1475 (669)
1462 (663)
1261 (572)
SHAPE OF ICE
Crescent Cube
ICE PRODUCTION PER CYCLE
31.6 lbs. (14.3 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2710(4.36)
2560(4.01)
WATER gal./24HR (gal./100 lbs.)
352(23.6)
755(49.3)
CEC/CEE TIER LEVEL
2
ENERGY STAR
YES
EXTERIOR DIMENSIONS (WxDxH)
48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet
1/2" FPT
- DRAIN
Outlet
3/4" FPT
- CONDENSATE DRAIN
3/8" OD Tube
CUBE CONTROL SYSTEM
Float Switch
HARVESTING CONTROL SYSTEM
Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL
Timer Controlled. Overflow Pipe
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Thermostat
COMPRESSOR
Hermetic, Model CS18K6E-PFV
CONDENSER
Air-Cooled Remote, Condenser Unit URC-22F
EVAPORATOR
Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL
Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-22F
REFRIGERANT CHARGE
R404A, 22 lb. 14.8 oz. (10400g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 7 lb. 11.5 oz.)
DESIGN PRESSURE
High 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION
Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch
ACCESSORIES -SUPPLIED
N/A
-REQUIRED
Ice Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONS
VOLTAGE RANGE
187 - 253 V
AMBIENT TEMP.
45 -100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE
10 - 113 PSIG