Hoshizaki KM-1601SAH/3 User Manual
Page 50
50
7. KM-1601SRH with URC-22F (remote air-cooled) (auxiliary codes: S-2 and later)
This data applies to units with an 11 l/min water valve. The 11 l/min water valve is either
part number 4A1176-04 or 4A5251-04 and has the part number stamped on the side of
the valve facing the front of the unit.
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
70/21
1531
694
1519
689
1426
647
80/27
1522
690
1503
682
1368
620
90/32
1519
689
1490
676
1371
622
lbs./day kg./day
100/38
1475
669
1462
663
1261
572
70/21
80/27
90/32
watts
100/38
70/21
755
2.86
637
2.41
555
2.10
80/27
665
2.52
481
1.82
444
1.68
90/32
637
2.41
352
1.33
294
1.11
gal./day m
3
/day
100/38
493
1.87
338
1.28
241
0.91
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
207
14.5
220
15.5
240
16.9
80/27
217
15.2
237
16.7
258
18.1
90/32
220
15.5
252
17.7
273
19.2
PSIG kg/cm
2
G
100/38
224
15.8
257
18.1
292
20.5
70/21
40
2.8
42
2.9
44
3.1
80/27
41
2.9
44
3.1
47
3.3
90/32
42
2.9
46
3.2
49
3.4
PSIG kg/cm
2
G
100/38
42
3.0
46
3.3
51
3.6
CONDENSER VOLUME
214 CU. IN (URC-22F)
26
26
28
2.5
5.5
3.6
4.6
3.5
2.6
4.8
25
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
2606
2604
2662
2710
2719
2560
2593
2604
28
30
31
34
2645
2693
2746
2780
29
26
27
29
2.0
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
4.1
3.4
4.6
2.3
TOTAL HEAT OF REJECTION FROM CONDENSER
21,000 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
2,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]