Hoshizaki KM-1601SAH/3 User Manual
Page 10
10
5. KM-1601SRH with URC-21F (remote air-cooled) (auxiliary codes: R-0; R-1; some S-1)
This data applies to units with an 8 l/min water valve. The 8 l/min water valve is part
number 3U0111-02 and has J248-032 stamped on the side of the valve facing the rear of
the unit.
Note: We reserve the right to make changes in specifications and design without prior
notice.
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE
12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*1583 (718)
1550 (703)
1435 (651)
Reference without *marks
80
1558 (707)
1507 (684)
1353 (614)
90
1550 (703)
*1472 (668)
1332 (604)
100
1503 (682)
1439 (653)
1203 (546)
SHAPE OF ICE
Crescent Cube
ICE PRODUCTION PER CYCLE
29.4 lbs. (13.3 kg) 1440 pcs.
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2640(4.3)
2440(3.7)
WATER gal./24HR (gal./100 lbs.)
255(17.3)
503(31.8)
EXTERIOR DIMENSIONS (WxDxH)
48" x 27 3/8" x 27 3/8" (1219 x 695 x 695 mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 275 lbs. (125 kg), Shipping 350 lbs. (159 kg)
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet
1/2" FPT
- DRAIN
Outlet
3/4" FPT
- CONDENSATE DRAIN
3/8" OD Tube
CUBE CONTROL SYSTEM
Float Switch
HARVESTING CONTROL SYSTEM
Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL
Timer Controlled. Overflow Pipe
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Thermostat
COMPRESSOR
Hermetic, Model CS18K6E-PFV
CONDENSER
Air-Cooled Remote, Condenser Unit URC-21F
EVAPORATOR
Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL
Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-21F
REFRIGERANT CHARGE
R404A, 24 lb. 14.6 oz. (11300g)
(Icemaker 15 lb. 3.4 oz. Cond. Unit 9 lb. 11.2 oz.)
DESIGN PRESSURE
High 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION
Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch
ACCESSORIES -SUPPLIED
N/A
-REQUIRED
Ice Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONS
VOLTAGE RANGE
187 - 253 V
AMBIENT TEMP.
45 -100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE