24

(5) Harvest Cycle

Same as the initial harvest cycle. See "II.B.1.b)(2) Initial Harvest Cycle."

Note: Unit continues to cycle until TBC is satisfied or power is turned off. The unit always

restarts at the 1-minute fill cycle.

(6) Shutdown

When ice contacts TBC bulb (TBC switch open), TBC shuts down the unit within
10 seconds. TBC is factory set, and generally no adjustment is required. However,
adjustment may be needed in some conditions, particularly at higher altitude locations.
CAUTION! Do not adjust S4 dip switch 7 out of the factory default position on this
model. This dip switch must be left in the factory default position or this unit will
not operate correctly.

Legend:

CB–control board; Comp–compressor; FMR–fan motor-remote; F/S–float switch;

HGV–hot gas valve; LLV–liquid line valve; PM–pump motor; TBC–thermostatic bin
control;

WV–inlet water valve