3. Controls and Adjustments

CAUTION

Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact
Hoshizaki Technical Support at 1-800-233-1940.

a) Default Dip Switch Settings

Note that the settings vary for KM-1601SRH/3 depending on the water valve installed.
The dip switches are factory set to the following positions:

S4 Dip Switch

Model

Auxiliary
Code

Water
Valve Part
Number

Code on
Water
Valve

S4 Dip Switch No.

1

2

3

4

5

6

7

8

9

10

KM-1601SAH/3
"G" Control Board

Dip switch settings for air-cooled units
are as listed, regardless of auxiliary
code.

OFF OFF ON ON ON ON ON OFF OFF OFF

KM-1601SWH/3
"E" Control Board

Dip switch settings for water-cooled
units are as listed, regardless of
auxiliary code.

OFF OFF OFF OFF ON ON OFF OFF OFF ON

KM-1601SRH/3
"E" Control Board

R-0, R-1,
some S-1

3U0111-02
(8 l/min)

J248-032

ON OFF ON OFF OFF OFF OFF OFF OFF OFF

Some S-1

3U0111-01
(15 l/min)

J248-030

ON OFF OFF OFF ON ON OFF OFF OFF OFF

S-2 & later

4A1176-04 (11 l/min)

V-1 (M) & later 4A5251-04 (11 l/min)

S5 Dip Switch (Do Not Adjust)

Model

S5 Dip Switch No.

1

2

3

4

5

KM-1601SAH/3

OFF OFF OFF OFF OFF

KM-1601SWH/3

Not Applicable

KM-1601SRH/3

1

2

3

4

5

6

7

8

9

10

ON

Freeze Timer (9 & 10)

Pump-Out Frequency Control (5 & 6)

Pump-Out Timer (3 & 4)

Harvest Timer (1 & 2)

Factory Use (8)

S4 Dip Switch

All Models

Harvest Pump Timer (7) KM-1601SAH/3 "G" Control Board

Bin Control Selector (7) KM-1601SWH/3 & KM-1601SRH/3

"E" Control Board

1

2

3

4

5

ON

Float Switch Selector (1)

Refill Counter (2 through 5)

S5 Dip Switch

KM-1601SAH/3 "G" Control Board