Hoshizaki KM-1601SAH/3 User Manual
Page 53
53
10. KM-1601SRH3 with URC-22F (remote air-cooled) (auxiliary codes: S-2 and later)
This data applies to units with an 11 l/min water valve. The 11 l/min water valve is either
part number 4A1176-04 or 4A5251-04 and has the part number stamped on the side of
the valve facing the front of the unit.
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
70/21
1530
694
1521
690
1414
641
80/27
1523
691
1508
684
1349
612
90/32
1521
690
1498
679
1359
616
lbs./day kg./day
100/38
1468
666
1465
665
1231
558
70/21
80/27
90/32
watts
100/38
70/21
704
2.66
599
2.27
531
2.01
80/27
624
2.36
462
1.75
435
1.65
90/32
599
2.27
348
1.32
301
1.14
gal./day m
3
/day
100/38
474
1.79
337
1.27
259
0.98
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
220
15.4
237
16.7
244
17.2
80/27
233
16.4
260
18.3
258
18.2
90/32
237
16.7
279
19.6
281
19.8
PSIG kg/cm
2
G
100/38
233
16.4
279
19.6
283
19.9
70/21
40
2.8
42
3.0
45
3.2
80/27
42
2.9
45
3.2
48
3.4
90/32
42
3.0
47.6
3.3
50
3.5
PSIG kg/cm
2
G
100/38
43
3.0
48
3.4
53
3.7
CONDENSER VOLUME
214 CU. IN (URC-22F)
TOTAL HEAT OF REJECTION FROM CONDENSER
26,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
4.5
2.4
30
27
27
29
2.2
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
4.1
3.4
29
31
32
34
2599
2659
2775
2770
2548
2575
2687
2780
2779
2490
2555
2575
26
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
26
27
28
2.6
5.3
3.6
4.5
3.5
2.7
4.7