Hoshizaki KM-1601SAH/3 User Manual
Page 46
46
3. KM-1601SWH (water-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
70/21
1492
677
1501
681
1419
643
80/27
1499
680
1513
686
1378
625
90/32
1501
681
1523
691
1408
639
lbs./day kg./day
100/38
1453
659
1496
679
1303
591
70/21
80/27
90/32
watts
100/38
70/21
1628
6.16
1697
6.43
2042
7.73
80/27
1681
6.36
1789
6.77
2272
8.60
90/32
1697
6.43
1866
7.06
2297
8.70
gal./day m
3
/day
100/38
1908
7.22
1967
7.44
2693
10.20
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
241
16.9
246
17.3
257
18.0
80/27
244
17.2
252
17.7
265
18.6
90/32
246
17.3
257
18.0
269
18.9
PSIG kg/cm
2
G
100/38
249
17.5
260
18.3
281
19.8
70/21
43
3.0
44
3.1
45
3.2
80/27
43
3.1
44
3.1
47
3.3
90/32
44
3.1
44
3.1
47
3.3
PSIG kg/cm
2
G
100/38
44
3.1
45
3.2
49
3.4
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
101 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
2.0
TOTAL HEAT OF REJECTION FROM CONDENSER
23,100 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
3.8
3.2
4.2
2.2
27
25
26
27
2335
2354
2400
2390
27
28
29
30
2319
2332
2375
2410
2408
2300
2325
2332
25
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
25
25
26
2.4
5.0
3.4
4.2
3.3
2.5
4.4