6. KM-1601SRH with URC-21F (remote air-cooled) (auxiliary codes: some S-1; S-2 and
later)
This data applies to units with a 15 l/min or 11 l/min water valve. The 15 l/min water valve
is part number 3U0111-01 and has J248-030 stamped on the side of the valve facing the
rear of the unit. The 11 l/min water valve is either part number 4A1176-04 or 4A5251-04
and has the part number stamped on the side of the valve facing the front of the unit.
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
70/21
1564
709
1547
702
1468
666
80/27
1551
703
1524
691
1415
642
90/32
1547
702
1505
683
1407
638
lbs./day kg./day
100/38
1512
686
1482
672
1317
597
70/21
80/27
90/32
watts
100/38
70/21
785
2.97
665
2.52
583
2.21
80/27
694
2.63
507
1.92
471
1.78
90/32
665
2.52
375
1.42
318
1.20
gal./day m
3
/day
100/38
519
1.97
361
1.37
266
1.01
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
213
15.0
226
15.9
245
17.2
80/27
223
15.7
243
17.1
263
18.5
90/32
226
15.9
257
18.1
277
19.5
PSIG kg/cm
2
G
100/38
230
16.2
262
18.4
296
20.8
70/21
40
2.8
41
2.9
44
3.1
80/27
41
2.9
43
3.1
47
3.3
90/32
41
2.9
45
3.2
48
3.4
PSIG kg/cm
2
G
100/38
42
3.0
46
3.2
51
3.6
CONDENSER VOLUME
441 CU. IN (URC-21F)
TOTAL HEAT OF REJECTION FROM CONDENSER
22,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
4.6
2.2
29
25
26
28
2.0
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
4.2
3.4
27
29
30
32
2684
2725
2752
2800
2650
2636
2671
2700
2712
2610
2630
2636
24
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
25
25
27
2.3
5.6
3.6
4.6
3.4
2.4
4.8