Honeywell VRX180 User Manual
Page 154

Programming Function Blocks and Features
Video Recorder – User Manual
140
Multiple Input Average (Multiple Avg)
The output CVn A1 is the instantaneous average of the assigned input points. The average is calculated
every scan cycle.
Table 4-47 describes the Multiple Average prompts. See Table 4-2 for additional prompts.
Table 4-47 Multiple Average Prompts
Prompt
Range/Selections
Definition
OUT LOW LIMIT
OUT HIGH LIMIT
OFF or number
Displayed output value will be clamped and will flash
when these limits are exceeded.
INPUT #1- INPUT #8
OFF, analog parameter,
number
Enter up to 8 inputs to be averaged