Environmental specifications
Specification Value
Temperature range*
Operating 10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping -30
°
C to 50
°
C (-22
°
F to 122
°
F)
Storage
-30°C to 60°C (-22°F to 140°F)
Maximum wet bulb
temperature
28
°
C (82.4
°
F)
Relative humidity
(noncondensing)**
Operating 10%
to
90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server specifications
Specification Value
Dimensions
Height
8.59 cm (3.38 in)
Depth
66.07 cm (26.01 in)
Width
44.54 cm (17.54 in)
Weight (maximum)
27.22 kg (60 lb)
Weight (no drives installed)
20.41 kg (47.18 lb)
Input requirements
Rated input voltage
100 to 132 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
10 A at 100 VAC
4.9 A at 200 VAC