beautypg.com

Hot-plug fan operation – HP ProLiant DL380 User Manual

Page 27

background image

Operations 27

4.

Remove the cable management arm.

Hot-plug fan operation

The server supports variable fan speeds. The fans operate at minimum speed until a temperature change

requires a fan speed increase to cool the server.
The server shuts down in the following scenarios:

At POST:

o

The BIOS suspends the server for 5 minutes if it detects a cautionary temperature level. If the

cautionary temperature level is still detected after 5 minutes, the BIOS performs an orderly

shutdown and enters Standby mode.

o

The BIOS performs an orderly shutdown if two or more fans have failed.

o

The server performs an immediate shutdown if it detects a critical temperature level.

IMPORTANT:

An immediate shutdown is a hardware-controlled function and it overrides any

firmware or software actions.

In the operating system:

o

The Health Driver performs an orderly shutdown if it detects a cautionary temperature level. If the

server detects a critical temperature level before the orderly shutdown occurs, the server performs

an immediate shutdown. Additionally, the Health Driver performs an orderly shutdown if more

than one fan is failed or removed.

o

When Thermal Shutdown is disabled in RBSU, the server performs an immediate shutdown if it

detects a critical temperature level.

IMPORTANT:

An immediate shutdown is a hardware-controlled function and it overrides any

firmware or software actions.