Back of the switch, Cl module slot, Rps input port – HP 6400CL User Manual
Page 17: Power connector, Back of the switch -9, Cl module slot -9, Rps input port -9, Power connector -9
1-9
Introducing the Switch
Back of the Switch
In
trodu
cin
g
the
Sw
it
ch
Back of the Switch
The back of both 6400cl Series switches look the same.
cl Module Slot
This switch supports one of two types of cl modules:
■
10-GbE Copper cl Module (J8434A) - provides two CX4 fixed copper ports
■
10-GbE Media-Flex cl Module (J8435A) - provides two flexible media slots
that support a number of different transceivers. See the ProCurve Switch
cl Modules Installation Guide
for more information on supported
transceivers.
RPS Input Port
The Series 6400cl Switch supports connectivity to a redundant power supply.
The “ProCurve 600 Redundant and External Power Supply (RPS/EPS)
(J8168A) is an accessory product for the Series 6400cl Switch devices. The
RPS/EPS provides redundant power to any one of up to six switch products,
to back up the power supply in the switch in case of loss of AC power. See
Step 8 of the installation instructions
Power Connector
The Series 6400cl Switch devices do not have a power switch; they are
powered on when connected to an active AC power source. These switches
automatically adjust to any voltage between 100--240 volts and either 50 or 60
Hz. There are no voltage range settings required.
Cooling vents - make sure this is not
obstructed for proper switch operation
ProCurve Series 6400cl Switch
RPS Input Port
Optional cl module slot
AC power connector