• If a power supply cord is used instead of the conduit

to connect the URC-12F-E to the fan motor junction
box of the KM-1300SRH-E, this cord should be rated
for outdoor use. At the entrance to the

URC-12F-E, a certified gland rated IPX4 should be

used where the cord enters the URC-12F-E.

• Recommended conductor size is .75mm

2

.

• Usually an electrical permit and services of a licensed

electrician are required.

1) Remove the four screws and the Panel of the remote

condenser.

2) Remove the two screws and the Junction Box Cover

on the remote condenser.

3) Remove the screw and the URC Fan Motor Junction

Box Cover on the icemaker.

4) Connect the Fan Motor leads in the Junction Box of

the remote condenser unit to the Fan Motor leads in
the Junction Box of the HOSHIZAKI remote air-cooled
icemaker. The Fan Motors in the URC-12F-E oper-
ate on 115 V AC. Do not connect the URC-12F-E to
the 230 V AC mains power supply.

5) Install an earth ground wire from the icemaker to the

remote condenser unit.

6) Replace the Panel and the Junction Box Cover in their

original positions.

Note: Care should be taken that the unit, line set and

Condenser contain the same type refrigerant
prior to making connections. Mixing of refriger-
ants will result in improper operation and pos-
sible damage to the refrigeration system. Make
the connections at the remote condenser first and
then at the icemaker.

7) Thoroughly leak test the coupling joints.

[d] ELECTRICAL CONNECTION

[d] ELECTRICAL CONNECTION

[d] ELECTRICAL CONNECTION

[d] ELECTRICAL CONNECTION

[d] ELECTRICAL CONNECTION

WARNING

WARNING

WARNING

WARNING

WARNING

THIS APPLIANCE MUST BE EARTHED

THIS APPLIANCE MUST BE EARTHED

THIS APPLIANCE MUST BE EARTHED

THIS APPLIANCE MUST BE EARTHED

THIS APPLIANCE MUST BE EARTHED

This remote condenser unit requires an earth that
meets the national and local electrical code require-
ments. To prevent possible severe electrical shock
to individuals or extensive damage to equipment,
install a proper earth wire to the icemaker. Turn off
the power supply before any maintenance, repairs
or cleaning is undertaken.

• This condenser unit must be connected to the Fan

Motor Junction Box on the icemaker.

• The opening for the power supply connection is 22.2

mm. to fit a conduit.