To test the flexible disk drive voltages – HP 16500B User Manual
Page 68
To test the flexible disk drive voltages
Refer to chapter 6, "Replacing Assemblies," for instructions to remove or replace covers and
assemblies.
W A R N I N G
Hazard voltages exist on the power supply, the CRT, and the CRT driver board. This
procedure is to be performed by service-trained personnel aware of the hazards involved,
such as fire and electrical shock.
Equipment Required
Equipment
Critical Specification
Recommended
Model/Part
Digitizing Oscilloscope
> 100 MHz Bandwidth
HP 54600A
1
Turn off the instrument, then remove the power cable. Remove the instrument
cover and the flexible disk drive.
2
Reconnect the disk drive cable to the rear of the disk drive. Turn the disk drive over
so that the solder connections of the cable socket are accessible.
3
Connect the power cable, then turn on the instrument.
4
In the Mainframe Test menu, select the Flexible Disk Test. Insert a disk that has
enough available bytes to run the test in the disk drive, then select Run-Repetitive.
Refer to "To run the self-tests" in this chapter if you need help accessing the test menu.
Troubleshooting
To test the flexible disk drive voltages
5–25