beautypg.com

Read-write error recovery mode page, Read-write error recovery page fields – HP C737990900 User Manual

Page 78

background image

78

Commands

Read-Write Error Recovery Mode Page

The Read-Write Error Recovery Mode Page has the following format:

Read-Write Error Recovery Page Fields:

7

6

5

4

3

2

1

0

0

PS (0)

Rsvd (0)

Page Code {01h}

1

Additional Page Length {0Ah}

2

Reserved (0)

TB (0)

Res (0)

EER (1)

PER [0]

DTE (0) DCR (0)

3

Read Retry Count

4–7

Reserved (0)

8

Write Retry Count

9–11

Reserved (0)

TB

Transfer Block

0 Always set to 0, meaning that an unrecoverable data block will not be transferred to

the host.

EER

Enable Early Recovery

1 The drive should attempt error correction before performing retries.

PER

Post Error. Although this bit is changeable, the drive’s internal behaviour always

corresponds to PER=0.

0 The drive does not report

CHECK CONDITION

for recovered errors. The DTE bit must

also be zero.

1 The drive reports

CHECK CONDITION

for recovered errors.

DTE

Disable Transfer on Error

0 Always set to 0, meaning that the drive will not terminate the transfer for errors

recovered within the limits established by the read-write error parameters.

DCR

Disable Correction

0 Always set to 0, meaning that the use of error correction codes for error recovery is

allowed.