beautypg.com

422 operation, Lk6 and lk7, Should be in posit – Eurotech Appliances VIPER / VIPER-LITE PXA255 User Manual

Page 99: E network. see, Rs485/422, Configuration – lk4, lk5, lk6 and lk7, 371h, For det, Required, Rs485/422 configuration – lk4, lk5, lk6 and lk7

background image

VIPER Technical Manual

Connectors, LEDs and jumpers

© 2007 Eurotech Ltd Issue E

99

RS485/422 configuration – LK4, LK5, LK6 and LK7 on JP1

These jumpers are used to enable/disable the RS485 receive buffer and RS485/422
line termination. See

436H

COM5 – RS422/485 interface

, page

437H

65

, for more details.

LK4 Description

(RS485 TX/RX) RS422 TX line
termination resistor (120

Ω) connected.

(RS485 TX/RX) RS422 TX line
termination resistor (120

Ω)

disconnected.

LK5 Description

RS422 RX line termination resistor
(120

Ω) connected.

RS422 RX line termination resistor
(120

Ω) disconnected.

LK6 & LK7

Description

RS422 full-duplex.

RS485 half-duplex.

Only fit LK4 and LK5 if the VIPER is at the end of the network.

VL

Default setting:

Default setting:

Default setting: