Location and installation/ventilation, Front view, Installation clearances 36” with low backguard – Hestan 30 Inch Freestanding Professional Gas Range Installation Manual User Manual

Page 9

background image

EN

©2019 Hestan Commercial Corporation

7

LOCATION AND INSTALLATION/VENTILATION

(CONTINUED)

W

V

3”

[7.6]

6”

[15.2]

11”

[28]

18”

[45.7]

G

11”

[28]

RECOMMENDED

GAS SHUT-OFF

VALVE LOCATION

ELECTRICAL

SUPPLY

LOCATION

5”

[12.7]

E

2-1/2”

[6.4]

INSTALLATION CLEARANCES 36” WITH LOW BACKGUARD

FRONT VIEW

VENT HOOD

MIN. CLEARANCE

TO NEAREST

COMBUSTIBLE

SIDE SURFACE

COMBUSTIBLE

MATERIALS

12”

[30.5]

FINISHED

FLOOR

DIMENSIONS IN

BRACKETS [ ] ARE

IN CM.

18” [45.7]

MIN.

COUNTERTOP

FULL OVERLAY

DRAWER FACE

FULL OVERLAY

CABINET DOOR FACE

1
8

" [3.2 mm]

NOTES:

SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.

APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.

“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS

ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.

“E” IS ELECTRICAL SUPPLY ZONE.

“W” IS APPLIANCE OPENING.

NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE

NEEDED FOR ADJACENT DRAWERS OR CABINETRY.

“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.

RANGE MODEL

W

V

(MIN)

KRG365

36” [91.4]

30” [76.2]

KRG364GD

36” [91.4]

30” [76.2]