Location and installation/ventilation, Front view, Installation clearances 36” with low backguard – Hestan 30 Inch Freestanding Professional Gas Range Installation Manual User Manual
Page 9
![background image](https://www.manualsdir.com/files/892241/content/doc009.png)
EN
©2019 Hestan Commercial Corporation
7
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
W
V
3”
[7.6]
6”
[15.2]
11”
[28]
18”
[45.7]
G
11”
[28]
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
ELECTRICAL
SUPPLY
LOCATION
5”
[12.7]
E
2-1/2”
[6.4]
INSTALLATION CLEARANCES 36” WITH LOW BACKGUARD
FRONT VIEW
VENT HOOD
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
COMBUSTIBLE
MATERIALS
12”
[30.5]
FINISHED
FLOOR
DIMENSIONS IN
BRACKETS [ ] ARE
IN CM.
18” [45.7]
MIN.
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
" [3.2 mm]
NOTES:
•
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
•
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
•
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
•
“E” IS ELECTRICAL SUPPLY ZONE.
•
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
•
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
RANGE MODEL
W
V
(MIN)
KRG365
36” [91.4]
30” [76.2]
KRG364GD
36” [91.4]
30” [76.2]