LOCATION AND INSTALLATION/VENTILATION

(CONTINUED)

COUNTERTOP

FULL OVERLAY

DRAWER FACE

FULL OVERLAY

CABINET DOOR FACE

1

8

" [3.2 mm]

11”

[28]

18”

[45.7]

G

11”

[28]

RECOMMENDED

GAS SHUT-OFF

VALVE LOCATION

ELECTRICAL

SUPPLY

LOCATION

5”

[15.2]

E

2-1/2”

[6.4]

6”

[15.2]

3”

[7.6]

12”

[30.5]

FINISHED

FLOOR

MIN. CLEARANCE

TO NEAREST

COMBUSTIBLE

SIDE SURFACE

COMBUSTIBLE

MATERIALS

DIMENSIONS IN

BRACKETS [ ]

ARE IN CM.

INSTALLATION CLEARANCES 36” WITH ISLAND TRIM

FRONT VIEW

W

V

RANGE MODEL

W

V

(MIN)

KRG365

36” [91.4]

30” [76.2]

KRG364GD

36” [91.4]

30” [76.2]

NOTES:

SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.

APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.

“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS

ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.

“E” IS ELECTRICAL SUPPLY ZONE.

“W” IS APPLIANCE OPENING.

NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE

NEEDED FOR ADJACENT DRAWERS OR CABINETRY.

“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.