Location and installation/ventilation, Front view, Installation clearances 36” with island trim – Hestan 30 Inch Freestanding Professional Gas Range Installation Manual User Manual
Page 11

EN
©2019 Hestan Commercial Corporation
9
LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
" [3.2 mm]
11”
[28]
18”
[45.7]
G
11”
[28]
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
ELECTRICAL
SUPPLY
LOCATION
5”
[15.2]
E
2-1/2”
[6.4]
6”
[15.2]
3”
[7.6]
12”
[30.5]
FINISHED
FLOOR
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
COMBUSTIBLE
MATERIALS
DIMENSIONS IN
BRACKETS [ ]
ARE IN CM.
INSTALLATION CLEARANCES 36” WITH ISLAND TRIM
FRONT VIEW
W
V
RANGE MODEL
W
V
(MIN)
KRG365
36” [91.4]
30” [76.2]
KRG364GD
36” [91.4]
30” [76.2]
NOTES:
•
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
•
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
•
“G” IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS
ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
•
“E” IS ELECTRICAL SUPPLY ZONE.
•
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
•
“V” IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.