beautypg.com

Gas connection – Hestan 30 Inch Freestanding Professional Gas Range Installation Manual User Manual

Page 16

background image

EN

©2019 Hestan Commercial Corporation

14

GAS CONNECTION

(CONTINUED)

GAS CONNECTION - NATURAL GAS (NG)

To ensure proper heating performance of this appliance, verify that the gas line supply pressure is

adequate. The appliance is supplied with a gas pressure regulator already installed. This regulator

is set for a supply (inlet) pressure of 7-14 inch WC [1.74-3.48 kPa] to maintain 5 inch WC [1.24 kPa]

nominal outlet (manifold) pressure.
Ensure that the service pipe supplying the appliance is fitted with a shut-off valve conveniently

positioned and easily accessible as an emergency gas shut-off.

GAS CONNECTION - LIQUID PROPANE (LP)

If you purchased an LP version of your appliance, it will be supplied with a gas pressure regulator

already installed. This regulator is set to maintain 10 inch WC [2.49 kPa] nominal outlet (manifold)

pressure.
Ensure that the service pipe supplying the appliance is fitted with a shut-off valve conveniently

positioned and easily accessible as an emergency gas shut-off.
When connecting to LP gas, verify the tank is equipped with its own high pressure regulator. The

pressure of the gas supplied to the appliance must be 11-14 inch WC [2.74-3.48 kPa].

LEAK TESTING

GENERAL
Although all gas connections on your Hestan appliance are leak tested at the factory prior to

shipment, a complete gas tightness check must be performed at the installation site due to possible

movement in shipment, or excessive pressure unknowingly being applied to parts of the unit.

Immediately check if the smell of gas is detected. Leak testing of the appliance shall be conducted

according to these instructions:
BEFORE TESTING

DO NOT SMOKE WHILE LEAK TESTING.

• Never leak test with an open flame.
• Make a soap solution of one part liquid detergent and one part water for leak testing purposes.
• Apply the solution to the gas fittings and flex hose by using a spray bottle or a brush.
TO TEST
• Make sure all control knobs are in the “OFF” position.
• Apply the soap solution to all fittings and flex hose.
• Turn the gas supply on.
• Check all connections from the supply line up to the regulator connection at the rear of the

appliance.

• Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas

supply, tighten any leaking fittings, turn the gas supply back on, and recheck.

• If you cannot stop a gas leak, turn off the gas supply and call the dealer where you purchased

your appliance.

• Do not use the appliance until all connections have been checked and do not leak.