LOCATION AND INSTALLATION/VENTILATION

(CONTINUED)

INSTALLATION CLEARANCES WITH ISLAND TRIM

SIDE VIEW

FINISHED

FLOOR

38-3/8 - 36-7/8”

[97.5 - 93.7]

TO COOKING

SURFACE

48-5/16”

[122.7]

DIMENSIONS IN BRACKETS [ ] ARE IN CM.

LOCATION OF GAS

AND ELECTRICAL

ON FLOOR

ISLAND

TRIM

For Island Trim installations,

counter surface should

have a cantilever surface

meeting the rear of

the Island Trim

MIN. CLEARANCE

TO COMBUSTIBLE

SURFACES WITH

ISLAND TRIM

COMBUSTIBLE

MATERIALS

30-13/16”

[78.3]

24-11/16”

[62.7]

12”

[30.5]

3”

[7.6]

MAX.

RECESS

DEPTH

APPLIANCE

TOP

COOKING

SURFACE

7” [17.7]

2-5/8”

[6.7]

HANDLE

END CAP

REF 1.12”

[2.84 cm]

VENTILATION REQUIREMENTS

It is strongly recommended that this appliance be installed with a Hestan vent hood. Due to the high

heat output of this range, it is very important that the hood and ductwork installation meets local

building codes and is installed by a qualified technician.
Do not use a down-draft style ventilation system.
Do not mount a microwave oven/ventilator combination above the range. These type of units do not

have sufficient airflow to remove the high heat output of this range and were not tested with this

type of appliance.
For non-Hestan approved vent hoods, the vent hood and/or blower unit must be rated for 1 CFM [1.7

m³/hr] for every 100 BTU [.03 kW]. (See rating plate for BTU rating of your unit.)
• If the range has a 12” Griddle, add an additional 200 CFM [340 m³/hr] to the blower capacity.