TROUBLESHOOTING

Problem

Possible Cause

Solutions

indicator light is on

during the drying cycle

Water supply error.

Check steam feeder drawer:
(1) Make sure the steam feeder is filled

with water to the MAX line.
(2) Make sure the steam feeder is seated

properly and the drawer is fully closed.
(3) Turn the dryer off then restart the

STEAM CYCLE.
Do not use distilled water; the water level

sensor in the steam generator will not

work.

Pump not working.

Unplug dryer and call for service.

The display shows d80,

d90, d95

The duct work is about 80%-95%

blocked.(“d80”,“d90” or “d95”

error code is displayed for 2

hours only)

House exhaust system blocked.

Do not use the dryer until the exhaust

system has been cleaned and/or repaired.

Using the dryer with a severely restricted

exhaust is dangerous and could result in

a fire or other property damage.
Check the outside dryer vent while the

dryer is operating to make sure there is

strong airflow.
If the exhaust system is extremely long,

have it repaired or rerouted.
Keep the area around the dryer clean and

free of clutter.
Check vent hood for damage or lint

clogging.
Make sure the area around the vent hood

is clear.