beautypg.com

Installation location requirements, Clearances, Warning – LG 27 Inch Electric Smart Dryer Owner Manual User Manual

Page 11

background image

11

INSTALLATION

Installation Location Requirements

WARNING

Read all installation instructions completely before installing and operating your dryer! It is important that you

review this entire manual before installing and using your dryer. Detailed instructions concerning electrical

connections, gas connections, and exhaust requirements are provided on the following pages.

The installation requires:

A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See

Venting the Dryer.

A grounded electrical outlet located within 2 ft. (61 cm) of either side of the dryer. See Connecting Electric

Dryers .

A sturdy floor to support the total dryer weight of 200 lb (90.7 kg). The combined weight of a companion

appliance should also be considered.

No other fuel-burning appliance can be installed in the same closet as a dryer.

Do not operate your dryer at temperatures below 45 °F (7 °C). At lower temperatures, the dryer might not shut off

at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored

in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do

not permit, installation of the dryer in garages, mobile homes or sleeping quarters. Contact your local building

inspector.

NOTE

The floor must be level, with a maximum slope of 1 inch (2.5 cm) under the entire dryer.

Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not

level.

For a garage installation, you will need to place the dryer at least 18-inch (46 cm) above the floor. The

standard pedestal is 15-inch (38.1 cm). You will need 18-inch (46 cm) from the garage floor to the bottom

of the dryer.

Clearances

Installation Spacing for Recessed Area or Closet Installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for clearances of

1 inch (2.5 cm) on the sides and rear. Recommended clearances should be considered for the following reasons:

Additional clearances should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional clearances should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are

required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.