32

INSTALLATION

Installation Test (Duct Check)

Once you have completed the installation of the

dryer, use this test to make sure the condition of the

exhaust system is adequate for proper operation of

the dryer. This test should be performed to alert you

to any serious problems in the exhaust system of

your home.

Your dryer features Flow Sense™, an innovative

sensing system that automatically detects

blockages and restrictions in dryer ductwork.

Keeping ductwork clean of lint buildup and free of

restrictions allows clothes to dry faster and reduces

energy use.

NOTE

The dryer should be cool before starting this test.

If the dryer was warmed up during installation, run

the AIR DRY cycle for a few minutes to reduce

the interior temperature.

To activate the installation test:

1

Remove the drying rack and literature, and

then close the door.

Do not load anything in the drum for this test, as

in may affect the accuracy of the results.

2

After you are pressed of Power button, you

will press and hold the Temp. and Signal

buttons in 3 seconds.

This button sequence activates the installation

test. The code

will display if the activation

is successful.

3

Press the START/PAUSE button.

The dryer will start the test, which will last about

2 minutes. The heat will be turned on and the

temperatures in the drum will be measured.

4

Check the display for results.

During the test cycle, monitor the Flow Sense™

display on the control panel. If no bars are

displayed, when the cycle ends, the exhaust

system is adequate. If the exhaust system is

severely restricted, the display will show four

bars. Other problems may also be shown with

error codes. Refer to the next page for error

code details and solutions.

NO BARS:

OK

FOUR BARS:

RESTRICTED

Four bars indicates that the exhaust system is

severely restricted. Have the system checked

immediately, as performance will be poor.

5

End of cycle.

At the end of the test cycle,

will display.

The test cycle will end and the dryer will shut off

automatically after a short delay.

Check the error code before you call for service

Error

Code

Possible

Causes

Solutions

tE1 or

tE2

Temperature

sensor failure.

Turn off the dryer and

call for service.

HS

Humidity

sensor failure.

Turn off the dryer and

call for service.

PS or

PF or

nP

Electric dryer

power cord is

not connected

correctly, or

house power

supply is

incorrect.

House fuse is

blown, circuit

breaker has

tripped, or

power outage

has occurred.

Check the power

supply or the

connection of the

power cord to the

terminal block. Refer

to the

Connecting

Electric Dryers

section of this

manual for complete

instructions.

Reset circuit breaker

or replace fuse. Do

not increase the fuse

capacity.

If the problem is a

circuit overload, have it

corrected by a qualified

electrician.

gAS

Gas supply or

service turned

off. (Gas

Model only.)

Confirm that house

gas shutoff and the

dryer gas shutoff are

both fully open.