INSTALLATION

Closet Ventilation Requirements

Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in the closet.

One upper vent opening with a minimum opening of 48 sq. in. (310 cm

2

) must be installed no lower than 6 feet

above the floor. One lower vent opening with a minimum opening of 24 sq. in. (155 cm

2

) must be installed no

more than one foot above the floor. Install vent grills in the door or cut down the door at the top and bottom to

form openings. Louvered doors with equivalent ventilation openings are also acceptable.

NOTE

There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of

vibration from one appliance to another. If there is enough vibration, it could cause appliances to make noise

or come into contact, causing paint damage and further increasing noise.

Installation Spacing for Recessed Area or Closet

Closet Door Vent

Requirements

3"

(7.6 cm)

14" max.*

(35.6 cm)

1"

(2.5 cm)

1"

(2.5 cm)

27"

(68.6 cm)

3"

(7.6 cm)

50

1

/

4

"

(127.5 cm)

29

1

/

2

"

(75.0 cm)

18" min.

(45.7 cm)

21

1

/

4

"

(54 cm)

48 in.

2

(310 cm

2

)

24 in.

2

(155 cm

2

)

* Required spacing
** For side or bottom venting, 2-inch (5.1 cm) of spacing is allowed

Installation Spacing for Cabinet

For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.
* Required spacing

7"* (17.8 cm)

7"* (17.8 cm)

5"*

(12.7 cm)

1"

(2.5 cm)

1"*

(2.5 cm)

1"

(2.5 cm)

29

1

/

2

"

(75.0 cm)

27"

(68.6 cm)