beautypg.com

Connecting the gas supply, High-altitude installations – LG 27 Inch Electric Smart Dryer Owner Manual User Manual

Page 26

background image

26

INSTALLATION

Connecting the Gas Supply

Installation and service must be performed

by a qualified installer, service agency, or the

gas supplier.

Failure to do so may result in fire,

explosion, or death.

Use only a new stainless steel flexible

connector and a new AGA-certified connector.

Failure to do so may result in fire, explosion, or

death.

A gas shutoff valve must be installed within 6 ft.

(1.8 m) of the dryer.

Failure to do so may result in

fire, explosion, or death.

The dryer is configured for natural gas when

shipped from the factory. Make sure that the

dryer is equipped with the correct burner nozzle

for the type of gas being used (natural gas or

propane gas).

Failure to do so may result in fire,

explosion, or death.

If necessary, the correct nozzle (for the LP

nozzle kit, order part number 383EEL3002D)

should be installed by a qualified technician

and the change should be noted on the dryer.

Failure to do so may result in fire, explosion, or

death.

All connections must be in accordance with

local codes and regulations.

Failure to do so may

result in fire, explosion, or death.

Gas dryers MUST exhaust to the outdoors.

Failure to do so may result in fire, explosion, or

death.

NOTE

This dryer is configured from the factory for

natural gas (NG). If the dryer is to be used with

propane (LP) gas, it must be converted by a

qualified service technician.

1

Make sure that the gas supply to the laundry

room is turned OFF and the dryer is unplugged.

Confirm that the type of gas available in your

laundry room is appropriate for the dryer.

2

Remove the shipping cap from the gas fitting at

the back of the dryer. Be careful not to damage

the threads of the gas connector when removing

the shipping cap.

3

Connect the dryer to your laundry room’s gas

supply using a new flexible stainless steel

connector with a 3/8-inch NPT fitting.

NOTE

DO NOT use old connectors.

4

Securely tighten all connections between the

dryer and your laundry room’s gas supply.

5

Turn on your laundry room’s gas supply.

6

Check all pipe connections (both internal and

external) for gas leaks with a noncorrosive leak-

detection fluid.

7

Proceed to Venting the Dryer.

3/8"

NPT gas

Connection

AGA/CSA-Certified

Stainless Steel

Flexible Connector

1/8" NPT Pipe Plug
Gas Supply Shutoff

Valve

High-altitude Installations

The BTU rating of this dryer is AGA-certified for

elevations below 10,000 feet.
If your gas dryer is being installed at an elevation

above 10,000 feet, it must be derated by a qualified

technician or gas supplier.