INSTALLATION

Connecting Gas Dryers

WARNING

To reduce the risk of fire or explosion, electric

shock, property damage, injury to persons, or

death when using this appliance, follow basic

safety precautions.

Gas Supply Requirements

As shipped from the factory, this dryer is

configured for use with natural gas (NG). It can

be converted for use with propane (LP) gas.

Gas pressure must not exceed 8-inch (20.3 cm)

water column for NG, or 13-inch (33 cm) water

column for LP.

A qualified service or gas company technician

must connect the dryer to the gas service.

Failure to follow these instructions may result

in fire, explosion, or death.

Isolate the dryer from the gas supply system

by closing its individual manual shutoff valve

during any pressure testing of the gas supply at

pressures greater than 1/2 psi (3.5 kPa).

Supply line requirements: Your laundry room

must have a rigid gas supply line to your dryer.

In the United States, an individual manual

shutoff valve MUST be installed within at least

6 ft. (1.8 m) of the dryer, in accordance with

the National Fuel Gas Code ANSI Z223.1 or

Canadian gas installation code CSA B149.1.

A 1/8-inch (0.3 cm) NPT pipe plug must be

installed.

Failure to do so may result in fire,

explosion, or death.

If using a rigid pipe, the rigid pipe should be ½

inch IPS. If acceptable under local codes and

ordinances and when acceptable to your gas

supplier, 3/8-inch (1 cm) approved tubing may

be used where lengths are less than 20 ft. (6.1

m). Larger tubing should be used for lengths

in excess of 20 ft. (6.1 m).

Failure to do so may

result in fire, explosion, or death.

Connect the dryer to the type of gas shown on

the nameplate.

Failure to do so may result in fire,

explosion, or death.

To prevent contamination of the gas valve,

purge the gas supply of air and sediment before

connecting the gas supply to the dryer. Before

tightening the connection between the gas

supply and the dryer, purge remaining air until

the odor of gas is detected.

Failure to do so may

result in fire, explosion, or death.

DO NOT use an open flame to inspect for gas

leaks. Use a noncorrosive leak detection fluid.

Failure to do so may result in fire, explosion, or

death.

Use only a new AGA- or CSA-certified gas

supply line (in compliance with the Standard

for Connectors for Gas Appliances, ANSI

Z21.24 • CSA 6.10) with flexible stainless steel

connectors.

Securely tighten all gas connections.

Failure to

do so may result in fire, explosion, or death.

Use Teflon tape or a pipe-joint compound

that is insoluble in propane (LP) gas on all

pipe threads.

Failure to do so may result in fire,

explosion, or death.

DO NOT attempt any disassembly of the dryer;

disassembly requires the attention and tools of

an authorized and qualified service technician

or company.

Failure to follow this warning may

result in fire, explosion, or death.

Electrical Requirements for Gas

Models Only

Do not, under any circumstances, cut or remove

the third (ground) prong from the power cord.

Failure to follow this warning may result in fire,

explosion, or death.

For personal safety, this dryer must be properly

grounded.

Failure to follow this warning may result

in fire, explosion, or death.

This dryer must be plugged into a 120-VAC, 60-

Hz. grounded outlet protected by a 15-ampere

fuse or circuit breaker.

Failure to follow this

warning may result in fire, explosion, or death.

Where a standard 2-prong wall outlet is

encountered, it is your personal responsibility

and obligation to have it replaced with a

properly grounded 3-prong wall outlet.

Failure to

follow this warning may result in fire, explosion, or

death.

Plug dryer into a

Connection

Gas Supply
Shut Valve

Plug

AGA/CSA-Cer
Stainless Steel Flexible
Connector

Plug dryer into a

120 VAC

,

60 Hz

grounded 3-prong

outlet.

WARNING

ELECTRIC SHOCK HAZARD

Failure to follow safety warnings could result in

serious injury or death.
This dryer is equipped with a three-prong

grounding plug for protection against shock

hazard and should be plugged directly into a

properly grounded three-prong receptacle. Do not

cut or remove the grounding prong from this plug.