beautypg.com

Solenoid check, Solenoid check -10 – Extron electronic 3000B User Manual

Page 89

background image

Exatron 3000B

www.exatron.com

5-10

Chapter 5 Diagnostics

;

;

;

;

Solenoid Check

__________________________________________________________________

This diagnostic tests port 03, located on PCB #5000-398, PAL 398-72, U5, U6.

TO ENTER THIS CHECK:

Handler displays DIAGNOSTICS
Press the [2] key.

Handler displays SOLENOID CHECK

Please refer to the following table. Press each of the handler terminal’s keypad keys [0] through [9].
Each key will turn on/off the handler's output cover LEDs and will set the corresponding handler solenoid
into an on/off test cycle. Please refer to Changeover Kit Supplement for specific solenoid information.

Terminal

Output

Corresponding

Key:

Cover LED:

Override Switch:

[1] Solenoid #1 __________

1

YELLOW BUTTON

[2] Solenoid #2 __________

2

WHITE BUTTON

[3] Solenoid #3 __________

3

ORANGE BUTTON

[4] Solenoid #4 __________

4

BLACK BUTTON

[5] Solenoid #5 __________

5

GREEN BUTTON

[6] Solenoid #6 __________

6

GREY BUTTON

[7] Solenoid #7 __________

7

RED BUTTON

[8] Solenoid #8 __________

8

BLUE BUTTON

[9] All Solenoids ON

ALL On

[0] All Solenoids OFF

ALL Off

Pressing the [Clear] button will flash the terminal's displayed message to confirm the handler is still in this
specific diagnostic check.

Press the [Enter] button to EXIT this diagnostic check and return to the DIAGNOSTICS message.