MANUAL MODE
You have pressed the [MANUAL] button. You may now make mechanical adjustments to the handler,
make changes to the Set UP, or run Diagnostics sequences as needed.
You may resume automatic handler operation by pressing the [RUN] button.
MEMORY ERROR
The handler's internal memory has failed self test.
Replace the 8085A CPU PCB, E
XATRON
part #3000-055.
MOD SET UP ? NO
Press the [Enter] button if no changes to the handler's set-up are required.
Press the [SET UP] button to make changes in the handler’s set-up.
MOD SET UP ? YS
If you do not wish to make any changes to the handler's set-up, press the [SET UP] button.
If you wish to make any changes to the handler's set-up, press the [Enter] button. The handler will now
scroll through all of the set-up routines listed below and wait for changes to be entered using the handler
controller keypad keys. Please review the Set Up Procedure in Chapter 4 of this manual for details
regarding each set-up.
PICK INTERFACE?
STOP ON FAIL ?
PICK PACKAGE ?
PLUNGE =
(Plunge-to-board changeover kits)
FULL TUBE =
MODEL 3000-B
Power-up message; no action required.