Exatron 3000b – Extron electronic 3000B User Manual
Page 78
Exatron 3000B
www.exatron.com
4-12
Chapter 4 Handler Setup
A
DRS
D
ESCRIPTION
ROM
RAM
O
PTIONS
C
OMMENTS
00E7
Pickup 1000
0
30 to 39
For Type 5B CO Kits only
Sets 1000’s digit, Home sensor to pick up point
00E8
Pickup 100
9
30 to 39
For Type 5B CO Kits only
Sets 100’s digit, Home sensor to pick up point
00E9
Pickup 10
0
30 to 39
For Type 5B CO Kits only
Sets 10’s digit, Home sensor to pick up point
00EA
Pickup 1
0
30 to 39
For Type 5B CO Kits only
Sets 1’s digit, Home sensor to pick up point
00EB
T Site 10000
0
30 to 39
For Type 5B CO Kits only
Sets 10000’s digit, Home sensor to Test Site point
00EC
T Site 1000
5
30 to 39
For Type 5B CO Kits only
Sets 1000’s digit, Home Sensor to Test Site point
00ED
T Site 100
0
30 to 39
For Type 5B CO Kits only
Sets 100’s digit, Home Sensor to Test Site point
00EE
T Site 10
0
30 to 39
For Type 5B CO Kits only
Sets 10’s digit, Home Sensor to Test Site point
00EF
T Site 1
0
30 to 39
For Type 5B CO Kits only
Sets 1’s digit, Home Sensor to Test Site point
00F0
Exit 10000
1
30 to 39
For Type 5B CO Kits only
Sets 10000’s digit, Home sensor to exit point
00F1
Exit 1000
0
30 to 39
For Type 5B CO Kits only
Sets 1000’s digit, Home sensor to exit point
00F2
Exit 100
8
30 to 39
For Type 5B CO Kits only
Sets 100’s digit, Home sensor to exit point
00F3
Exit 10
0
30 to 39
For Type 5B CO Kits only
Sets 10’s digit, Home sensor to exit point
00F4
Exit 1
0
30 to 39
For Type 5B CO Kits only
Sets 1’s digit, Home sensor to exit point
00F5
Password On/Off
00
00, FF
Sets the controller password protection for the handler.
Set to 00, password is required to make changes to the
handler set up. Set to FF, password is not required.
F
ACTORY SET PASSWORD IS
: 789.
00F6
Check I-Lock
00
00, FF
FF = No Check
00 = Will check optional CO Kit cover interlock, will stop
the handler if the interlock is open.
00F7
Plunge Power
44
40, 44
40 = Standard Power.
44 = More Torque.
Standard Power cuts power to the coils when the Z-
motor stops. This is a power-saving function. More
Torque leaves full power on the coils when the Z-motor
stops.
For Type 4 Plunge to Board CO Kits Only
00F8
Plunge Delay
0A
00 to FF
Time delay between each step during Z-motor plunge.
Delay may be set in .25 millisecond increments: 01 =
.25 msec delay. 02 = .50 msec delay, etc.
For Type 4 Plunge to Board CO Kits Only
00F9
Soft Plunge Step
0A
00 to FF
Sets the number in HEX of full steps in this special
reduced-impact plunger sequence. F
OR EXAMPLE
: 0A = 10
full steps. If the handler is set to Half Step (see below)
this number is automatically doubled. DO NOT USE
MORE THAN 100 STEPS.
For Type 4 Plunge to Board CO Kits Only