beautypg.com

Load device, Load empty tube, Load eprom>ram – Extron electronic 3000B User Manual

Page 112: Load remote ram, Loader go left, Loader go right, Loader jam, Loading master, Low going pulse

background image

Exatron 3000B

www.exatron.com

6-11

Chapter 6 Display Dictionary

LOAD DEVICE ?

Please refer to SET P/V/L MODE? message later in this section.

LOAD EMPTY TUBE

An output tube was removed after the handler selected an output bin, but before the sort shuttle arrived at
that tube. Place an empty tube at the output that has the flashing output cover LED.

LOAD EPROM>RAM

The handler has reloaded its RAM set-up data with settings stored in EPROM. For your reference only.

LOAD REMOTE RAM

The PC has sent new handler set-up data to the handler's RAM. Any settings previously made by the
operator will be changed. No action is required, although we recommend verifying that the settings are
correct after this message turns off.

LOADER GO LEFT

The octoloader is moving to the left.

LOADER GO RIGHT

The octoloader is moving to the right.

LOADER JAM

The handler is detecting devices at the output of the octoloader / input to the handler, although no devices
are at the index section.

1. There are devices jammed at the output of the octoloader.

2. Clear the jammed device(s) manually. When you have done so, the handler will automatically

restart.

3. Or press the [Clear] button to wiggle the octoloader and possibly clear the jammed device(s).

4. Or press the [0] key: ALL MOTORS OFF, then press [Enter] to display ALIGN MOTORS ?

and realign the octoloader plate to the handler input. Press [Enter] again to turn the motors
back on.

5. Or use Diagnostics/OCTO/INDEX Check: Input Sensor Check to verify that input sensors 6,

7, 8 are working correctly. Please refer to Diagnostics Chapter 5.

LOADING MASTER

The handler is using the PROGRAM RS-232 interface. The handler is currently loading a master device
into the programmer. You may press the [Clear] button to abort the test and sort the device to a fail
tube.

LOW GOING PULSE

This is a communications interface for older applications only and is not normally used. Please refer to
Interface Information, Chapter 3 for details.