Exatron 3000b – Extron electronic 3000B User Manual
Page 73
![background image](/manuals/87010/73/background.png)
Exatron 3000B
www.exatron.com
4-7
Chapter 4 Handler Setup
A
DRS
D
ESCRIPTION
ROM
RAM
O
PTIONS
C
OMMENTS
009A
Count Mask
00
00 to FF
Allows the operator to designate a bin or bins that will
ignore the pre-defined full tube count. This is useful
when using bulk/bucket outputs.
A total count is maintained, but the output/tube selected
will never “fill”.
For example, bit map 10 = Sort 5; 00 = No masking; 08
= Mask bin 4.
009B
Baud Rate
RS-232
0C
See Table
in
Interface
Chapter
Stores the baud rate of the RS-232 interface between
the handler system and the PC.
Must be set to 0C for E
XATRON
S
UPER
Interface.
0C = 9600 BAUD
009C
Data Format
03
See Table
in
Interface
Chapter
Stores the parity/stop/data bits.
Must be set to 03 for E
XATRON
S
UPER
Interface.
03 = No Parity, 8 bits, 1 stops
07 = No Parity, 8 bits, 2 stops
009D
Wiggle Shuttle
00
00, FF
To wiggle the shuttle during sorting.
00 = Wiggle shuttle
FF = Wiggle turned off
009E
Time Out
20
00 to FF
A timed delay before the handler aborts the test and
turns off all solenoids. Counts down in HEX in 1 second
steps. When this address is set to 00, the system will
never time out.
009F
Shuttle Thump
00
00, FF
To “thump” the shuttle during a jam by firing the
solenoid.
00 = Thump the shuttle
FF = Thump turned off
00A0
FF
00A1
FF
00A2
Index Delay
00
Type 5B Kits only, Adds delay for DUT to fall into the
pick up location just after being “indexed” Counts down
in 10 msec steps
00A3
Settling Delay
19
Type 5B Kits only, Adds delay for DUT to settle down
into the pick up location just before being picked up.
Counts down in 10 msec steps
00A4
T Site Out Delay
05
Type 5B Kits only, Adds delay for DUT to fall past the
exit sensor after leaving the test contacts. Counts down
in 10 msec steps
00A5
Opto Input
FF
00, FF
Enables optional Opto Isolation PCB Option. Handler
must be equipped with optional
5000-D76 Opto Interface PCB
00 = Turn option on
FF = turn option off
00A6
Check Sort Reset
FF
00, FF
Allows the handler to check whether all sort signals are
OFF at the start of the test. To enable this option, set
this address to 00. To disable this option, set this
address to FF. Set this to FF when using LED checker
boxes for simulation purposes.