Exatron 3000b – Extron electronic 3000B User Manual
Page 77
Exatron 3000B
www.exatron.com
4-11
Chapter 4 Handler Setup
A
DRS
D
ESCRIPTION
ROM
RAM
O
PTIONS
C
OMMENTS
00D6
Plunge Steps 10
4
30 to 39
For Plunge to Board Type 4 Changeover Kits. Sets the
10s digit of the Z-motor plunge to contact steps. Set as
ASCII Number.
00D7
Plunge Steps 1
6
30 to 39
For Plunge to Board Type 4 Changeover Kits. Sets the
1s digit of the Z-motor plunge to contact steps. Set as
ASCII Number.
00D8
2
nd
Start Width
00
00 to FF
Sets the width of an available second start pulse to be
used in the event that the tester has a problem with the
handler’s standard start pulse timing. Use this 2
nd
Start
feature only to solve interface problems flagged by the
error messages, “SORT NOT RESET” and/or “MULTI
SORT ERROR.” S
EE
I
NTERFACE
C
HAPTER FOR FURTHER
DETAILS
.
00D9
2
nd
Start Delay
00
00 to FF
Sets a time delay before the handler sends an available
second start pulse to the tester. Counts down in HEX in
1 millisecond steps. The second start pulse feature is
used in the event that the tester has a problem with the
handler’s standard start pulse timing. Use this 2
nd
Start
feature only to solve interface problems flagged by the
error messages, “SORT NOT RESET” and/or “MULTI
SORT ERROR.” S
EE
I
NTERFACE
C
HAPTER FOR FURTHER
DETAILS
.
00DA
Soak Time 1.0 S
0
30 to 39
Sets a per test cycle “Soak Delay” for Model 3010 Hot
Rails Sets 1.0 second digit.
00DB
Soak Time 0.1 S
0
30 to 39
Sets a per test cycle “Soak Delay” for Model 3010 Hot
Rails Sets 0.1 second digit.
00DC
Label Size
04
00 to 06
Sets default label size
01 = 300 DIP
02 = 600 DIP
03 = 20 PLCC
04 = 28/32 PLCC
05 = 44 PLCC
06 = 5 x 7 LCC
00DD
300 DIP V Delay
06
00, 30
Sets label print to vacuum on delay for 3000BL
00DE
600 DIP V Delay
20
00, 30
Sets label print to vacuum on delay for 3000BL
00DF
20 PLCC V Delay
0A
00, 30
Sets label print to vacuum on delay for 3000BL
00E0
28/32 V Delay
15
00, 30
Sets label print to vacuum on delay for 3000BL
00E1
44 PLCC V Delay
19
00, 30
Sets label print to vacuum on delay for 3000BL
00E2
5 x 7 V Delay
10
00, 30
Sets label print to vacuum on delay for 3000BL
00E3
FF
00E4
FF
00E5
5B Electronics
FF
5B, FF
Sets the handler to do self tests on handlers equipped
with Type 5B electronics, (Extra RS-232 port)
FF = No 5B checks
00E6
Pickup 10000
0
30 to 39
For Type 5B CO Kits only
Sets 10000’s digit, Home sensor to pick up point